(7) Speed control by manual pulse generation operation
The speed during positioning control by manual pulse generator operation is a speed corresponding to the No. of
input pulses per unit time, and can be obtained using the following equation.
Output command frequency = Input frequency [Cd.20] Manual pulse generator 1 pulse input magnification