Chapter 15 Troubleshooting; Checking Errors Using Gx Works2 - Mitsubishi Electric MELSEC-L LD75P User Manual

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

CHAPTER 15
15.1

Checking Errors Using GX Works2

Error codes corresponding to the errors occurred in the LD75 can be checked either on the following screen of GX
Works2.
Select the screen according to the purpose and usage.
• "Module's Detailed Information" screen.
• "Error History" screen.
(1) Checking errors on the "Module's Detailed Information" screen
Select [Diagnostics]  [System Monitor] on GX Works2.
Select "LD75" for "Main block" and click the [Detailed information] button.
The "Module's Detailed Information" screen for the LD75 appears and the error code, error details, and corrective
actions can be checked.
640
TROUBLESHOOTING
The latest error code is displayed.
The error history is displayed.
Contents of the error code selected
in the error history and solution for
it is displayed.