Appendix 4.4
(1) Connection example of LD75D and R series (Differential driver)
LD75D
*1
PULSE F+
15
PULSE F-
16
17
PULSE R+
PULSE R-
18
CLEAR
13
14
CLEAR COM
PG05
9
PG0 COM
10
READY
11
RDY COM
12
A19
PULSER A+
PULSER A-
B19
A20
PULSER B+
PULSER B-
B20
DOG
3
1
FLS
RLS
2
STOP
4
CHG
5
COM
6
COM
7
PULSE COM
*1
The logic for each I/O terminal can be changed with "[Pr.22] Input signal logic selection" and "[Pr.23] Output signal logic
selection" in detailed parameters 1. (Negative logic is used for all terminals in the example above.)
*2
The LD75D upper limit (FLS) and lower limit (RLS) are used in the OPR retry function. Set these signals inside the
servo amplifier limit switches.
Refer to the manual of the servo amplifier for information on the servo amplifier side wiring and various signal wire
*3
shields not shown above.
*4
Use the same logic (positive logic/negative logic) for the LD75D and servo amplifier. The LD75D is initially set to
negative logic.
*5
This indicates the distance between the LD75D and R series.
Connection examples with servo amplifiers
manufactured by SANYO DENKI Co., Ltd.
Within 2m
5V
+5V
A
Manual pulse
B
generator
MR-HDP01
0V
5G
Near-point dog
*2
Upper limit
*2
Lower limit
STOP
External command
*5
24G
P24V
APPENDICES
*4
R series
*3
26
F-PC
27
F-PC
R-PC
28
29
R-PC
34
CLR (CONT4)
7
ZO
8
ZO
37
S-ON (CONT1)
F-OT (CONT6)
32
33
R-OT (CONT5)
50
CONT-COM
47
SG
48
SG
733
A