hit counter script

Appendix 7 When Using Gx Developer Or Gx Configurator-Qp; Appendix 7.1 Operation Of Gx Developer - Mitsubishi Electric MELSEC-L LD75P User Manual

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

Appendix 7
This section describes the operation method when GX Developer or GX Configurator-QP is used.
(1) Applicable software version
For applicable software versions, refer to the following.
 MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and Inspection)
Appendix 7.1
With GX Developer, set the type of the module to be connected and the I/O signal range in the I/O assignment tab of
the PLC parameter dialog box.
(1) I/O assignment tab
(a) Operating procedure
1.
Open the "L Parameter" dialog box.
Parameter  [PLC parameter]  [I/O assignment]
2.
Configure settings.
Set the following items.
Item
Type
Model
Points
Start XY
When Using GX Developer or GX
Configurator-QP
Operation of GX Developer
Select "Intelli.".
Enter the module model name.
Select "32point".
Enter the start I/O number for the positioning module.
Description
APPENDICES
A
767

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d

Table of Contents